This tool calculates the Noise floor of a spectrum analyzer. The noise floor represents the weakest possible signal that can be detected by the instrument.
Calculator
Enter
- Displayed Average Noise Level (DANL)
- Resolution Bandwidth
- Transducer Factor (LISN)
- Correction Factor
Formula
Spectrum Analyzer Noise Floor = DANL + 10*Log10(RBW) + Correction Factor + Transducer Factor
Correction and Transducer factors are used in EMC testing and this is also called the System Noise Floor.
Example Calculation
For a DANL of -151 dBm/Hz and RBW = 1 MHz, Transducer Factor = 3 dB and Correction Factor = 3 dB, the noise floor of the spectrum analyzer is -85 dBm. The tool also provides the Watt equivalent or 3.16*10-12 W.
The picture below shows the variation of noise level with bandwidth
Practical Note
The lower the noise floor of the spectrum analyzer, the better it is at detecting weaker signals and consequently the more expensive it is.
A good spectrum analyzer will have a noise floor of -160 dBm/Hz or better at lower frequencies.
Related Posts
- Receiver Sensitivity (every spectrum analyzer is a radio receiver)
- dBm per Hz to dBm
- Spectrum Analyzer Scan Rate Calculator
- Resolution Bandwidth Calculator